In addition to conventional atmospheric corrosion resistant steels, JFE Steel has developed corrosion resistant steels for sea side areas, where ordinary atmospheric corrosion resistant steel is not practical without painting, because of salty exposure.These steels are the standard type(Type1),which includes 1.5%Ni-Mo, and higher resistant type(Type2) including 2.5%Ni. For the purposes of preventing stain by watery rust at the initiation of exposure in atmospheric environment, JFE markets the rust stability accelerating paint "CUPTEN COAT M" and "e-RUS".
| Designation; | Thickness (mm) | Equivalent JIS standard |
|---|---|---|
| JFE-ACL400 Type1 | 6-100 | SMA400W-Mod |
| JFE-ACL490 Type1 | SMA490W-Mod | |
| JFE-ACL570 Type1 | SMA570W-Mod | |
| JFE-ACL400 Type2 | 6-100 | SMA400W-Mod |
| JFE-ACL490 Type2 | SMA490W-Mod | |
| JFE-ACL570 Type2 | SMA570W-Mod |
| Designation | Cu | Ni | Cr | Mo | |
|---|---|---|---|---|---|
| JFE-ACL400 Type1 | - | 1.00-2.00 | - | 0.20-0.60 | |
| JFE-ACL490 Type1 | |||||
| JFE-ACL570 Type1 | |||||
| JFE-ACL400 Type2 | 0.30-0.50 | 2.00-3.00 | - | - | |
| JFE-ACL490 Type2 | |||||
| JFE-ACL570 Type2 | |||||
| (Reference) JISG3114 |
SMA400W | 0.30-0.50 | 0.30-0.50 | - | - |
| SMA490W | |||||
| SMA570W | |||||
| Grade | Tensile properties | Charpy impact | ||||
|---|---|---|---|---|---|---|
| YP or YS N/mm2 |
UTS N/mm2 |
Test temp. oC |
Absorbed Eng. J |
|||
| JFE-ACL400 | A | ≥235 | 400-540 | - | - | |
| B | 0 | ≥27 | ||||
| C | 0 | ≥47 | ||||
| JFE-ACL490 | A | ≥355 | 490-610 | - | - | |
| B | 0 | ≥27 | ||||
| C | 0 | ≥47 | ||||
| JFE-ACL570 | ≥450 | 570~720 | -5 | ≥47 | ||