  Abstract
  JFE Engineering’s advanced stoker-type incinerator the “Hyper 21 Stoker System” is the first municipal solid waste incinerator which has adopted the new technology called “high-temperature air combustion technology.” With this technology, the system realizes stable combustion under low excess air condition, which results in reduction of NOx, dioxins and flue gas flow rate. The system also treats waste from combustion to ash melting with high efficiency and low pollutant emissions. The Hyper 21 Stoker System described in this paper demonstrated excellent operational stability and easy operating features, while also minimizing environmental pollutants, improving heat (energy) recovery rate, and reducing operational costs.
  