Comparison of magnetic characteristics (JFE in-house data) : Rolling direction, shear cross-section
Material
Thickness
(mm)
DC max
relative
permeability
Saturation
magnetiza-
tion (T)
Magnetic
flux density
B
8
(T)
Magnetic
flux density
B
25
(T)
Core loss (W/kg)
W10/50
W10/400
W10/1k
W5/2k
W2/5k
W1/10k
W0.5/20k
JNHF-Core
0.10
0.20
4.100
3.900
1.88
1.94
1.15
1.09
1.44
1.47
1.1
1.2
10.1
14.5
30.0
51.6
20.2
29.1
11.5
17.9
7.1
12.7
5.0
9.5
JNEX-Core
0.10
23.000
1.80
1.29
1.40
0.5
5.7
18.7
13.7
11.3
8.3
6.9
Non-oriented silicon steel
0.23
92,000
0.23
1.92
1.96
0.3
7.8
35.0
33.0
33.0
30.0
32.0
Amorphous
0.025
300.000
1.50
-
-
0.1
1.5
5.5
8.1
4.0
3.6
3.3
*W10/50 is the core loss at 50 Hz, 1 T (=10kG) when the magnetic flux sine wave is excited