ì軓S‹Z•ñ
KAWASAKI STEEL GIHO
Vol.18 (1986) No.2
¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡¡

‡‹à‰»—n—ZˆŸ‰”‚ß‚Á‚«‘wFe”Z“x‚̘A‘±‘ª’è•û–@
Continuous Measurement of Fe Content in Galvannealed Coating

ì•Ó@‡ŽŸ(Junji Kawabe)@“¡‰i@’‰’j(Tadao Fujinaga)@–Ø‘º@@”£(Hajime Kimura)@‰Ÿê@˜a–ç(Suzuya Oshiba)@ˆÀ•”@’‰œA(Tadahiro Abe)@‚‹´@r—Y(Shun-yu Takahashi)
—vŽ| :
‡‹à‰»—n—ZˆŸ‰”‚ß‚Á‚«|”‚̂߂Á‚«‘wFe”Z“x‚Æ•t’…—ʂ𓯎ž‚É‘ª’è‚·‚é•û–@‚ðC•½sƒr[ƒ€ŒõŠwŒnXü‰ñÜ‘•’u‚ð—p‚¢‚ÄŒŸ“¢‚µ‚½B‚»‚ÌŒ‹‰ÊCCr-Kƒ¿ü‚É‚æ‚é‰ñÜ‚Å‚ÍC2ƒÆ‚ª90‹`150‹‚͈̔͂ɃÂ1(103)Cƒ¡(633)CƒÅ(004)‚¨‚æ‚у¿-Fe(200)‚̉ñ܃s[ƒN‚ª”F‚ß‚ç‚ê‚éB‚±‚ê‚ç‚̃s[ƒN‹­“xIƒÂ1C1ƒ¡‚¨‚æ‚Ñ1ƒÅ‚ÍFe”Z“x‚ÆCIƒ¿-FO‚Í‚ß‚Á‚«•t’…—Ê‚Æ‚»‚ꂼ‚ê‹­‚¢‘ŠŠÖ‚ª‚ ‚éB1ƒ¡‚ÆIƒ¿-FO‚ð•Ï”‚Æ‚µ‚Äd‰ñ‹A‚µ‚½Œ‹‰ÊC‚»‚̉ñ‹AŽ®(ŒŸ—Êü)‚ð—p‚¢‚Ä‚ÌFe”Z“x‚¨‚æ‚Ñ‚ß‚Á‚«•t’…—Ê‚Ì‘ª’踓x‚ÍC³Šm‚³(ƒÐd)‚Å‚»‚ꂼ‚ê0.6“FeC2.5g/m2‚Å‚ ‚éB‚±‚ê‚ç‚Ì’mŒ©‚©‚çC‡‹à‰»—n—ZˆŸ‰”‚ß‚Á‚«|”‚̂߂Á‚«‘wFe”Z“x‚¨‚æ‚Ñ•t’…—Ê‚ðCCGL“à‚ŘA‘±“I‚É‘ª’è‚Å‚«‚錩’Ê‚µ‚𓾂½B
Synopsis :
The measuring method of Fe content and coating weight of galvannealed steel sheet has been developed using diffractometer which has a parallel beam optical system. Many peaks of diffracted X-rays which show ƒÂ1(103), ƒ¡(633), ƒÅ(004), ƒ¿-Fe(200) and so on have been found in the range of 2ƒÆ=90‹`150‹(by Cr-Kƒ¿). Intensities of these peaks, i.e., IƒÂ1, 1ƒ¡, IƒÅ are closely related to Fe content, and Iƒ¿-FO has a very close correlation with coating weight. Two calibration curves for Fe content and coating weight, which have been regression analyzed using 1ƒ¡ and Iƒ¿-FO as variables, give the higher measuring accuracy by mean-square errors of 0.6% for Fe content and 2.5g/m2 for coating weight.
–{•¶iPDF: 7P/336kbj




(c)JFE Steel Corporation, 2003